Repaired this unit about a month ago after the son had tried to use the door as a trampaleen.
Now it refuses to heat the water.
I have checked the circuit from module to element and back to module and it reads ok. No dry joints on module. There is 240v to the heater but must be missing a netural. I can only think it is the module or is there something I am missing???
dont know why neutral is missing when you checked for voltage and continuity,but as helpful little jimmy used door as trampoline I would check loom for breakages,ie when opened loom may be ok but when shut it may be oc or visa versa just a thought
Fault found at mains terminal block where neutral wire have corroded somewhat. replace terminal connectors and the heat was on. Block is situated at front towards left hand side of base. No cover on it to stop water getting into it if door leaks?