CAPLE WMI2001

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #50000
    Minge
    Participant

    Hi!

    I am having problems with this appliance. Originally the error code c03 was appearing. All components etc test ok. I replaced the pcb from obtained from connect, and had to select the spin speed after turning on by pressing a few buttons (i think) to 1100 to fit the machine spin speed.

    Now though error f05 is appearing towards the end of the cycle and does not take the conditioner. I replaced the pressure switch. Does any one have any ideas/experience on these? Do you need to configure the pcbs correctly? if so how? the programmes seem to be in correct order and times etc look ok.

    Many thanks.

    #302992
    cab
    Participant

    Re: CAPLE WMI2001

    From memory this is a Fagor, the pcb does need configuring.
    fo1 filling
    fo2 drain
    fo4 door
    fo5 ntc
    fo6 no heat
    fo7 overfill
    fo8 motor
    fo9 motor inversion
    fo10 internal domotic error?
    fo11 external domotic

    co3 imballance

    #302993
    bazza500
    Participant

    Re: CAPLE WMI2001

    I think I have the configuration procedure on my laptop.

    PM me your email and I’ll forward it this evening.

Viewing 3 posts - 1 through 3 (of 3 total)