lg wm14220fd pump problem ?

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #50241
    jasper
    Participant

    hi guys called to a blocked pump on this m/c took it out , full of gunk,and fitted a new pump,switched it on, selected 1 min drain,nothing….??
    took the new unit out etc,and refitted, still no drain or pump out ..??..
    after checking again,nothing?.
    it is the m/c type with two!!..pumps ,oh and after fiddling about for ages,the customer tells me ,her husband,had the m/c,upside down!!!!
    ggggggggggggrrrrr, any suggestions,apart from the obvious,!! woul be helpful,…
    jasper…

    #304090
    electrofix
    Moderator

    Re: lg wm14220fd pump problem ?

    typical customer leave the best bits to last


    lol

    Dave

    #304091
    Jonah
    Participant

    Re: lg wm14220fd pump problem ?

    If he has turned it upside down the main PCB Control module in the facia probably got wet, what a numpty :rolls: , all I can suggest is check you are getting supply voltage at the pump when on drain 🙁

    #304092
    BobHope
    Participant

    Re: lg wm14220fd pump problem ?

    hi jasper

    just a thought you have changed the drain pump and not the recirculation pump ?

    Bob.

    #304093
    jasper
    Participant

    Re: lg wm14220fd pump problem ?

    hi guys thanks for your replies,ie, jonah,electrofix,and bob hope,
    me thinks i will pass on to big LG in the sky.