Neff d/w Flow meter?

Viewing 6 posts - 1 through 6 (of 6 total)
  • Author
    Posts
  • #50280
    Kirk
    Participant

    Where is the flow meter in this D/W eng couldn’t find it, does it have impeller type.
    Towards end of program fills for 5 secs then MTs for 5 secs continuously

    Model S4443W7/GB/01 FD8309

    #304252
    scots
    Participant

    Re: Neff d/w Flow meter?

    Dont think this model has a flow meter, think it has a float inside the sump.

    There are some Bosch with a flow meter similar to the Diplomat type, located at the LHS rear beside the inlet valve and they do fail.

    But as I said I dont think your DW has it.

    Brian

    #304253
    PINKY
    Participant

    Re: Neff d/w Flow meter?

    No flow meter on this one its got mushroom thingy in the base . Sticky float ?

    #304254
    Kirk
    Participant

    Re: Neff d/w Flow meter?

    Thanks Scots & Pinky

    What does this look like? is it inside cabinet or underneath,

    Thanks again Kirk

    #304255
    nomadPaul
    Participant

    Kirk , the level on this is controlled by a float in the sump. As you look down into the sump , there is a small circular cover at about the 5 o’clock position. Pop this cover off to revel the float in its channel. You may find this float is all gunged up and isn’t rising as the water fills the tub. Hence you get an overfill condition and a constant fill/drain cycle.

    Take out the float – making a note of its orientation , and give it a good clean. Also clean the float channel with some hot water so that the float travels freely up and down without stickng.

    Hopefully this should clear your fault

    #304256
    Kirk
    Participant

    Re: Neff d/w Flow meter?

    Thanks nomadPaul

    Kirk

Viewing 6 posts - 1 through 6 (of 6 total)