Hotpoint TCM570 cond. dryer

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #50292
    Kez
    Participant

    Hi We are having problems with this Tumble dryer. Fault of tripping the electrics. Fitted new pump and the container is filling with water nicely, however water is still getting across to the heater housing obviously causing the electrics to trip still. Any ideas? Cheers Kez

    #304294
    electrofix
    Moderator

    Re: Hotpoint TCM570 cond. dryer

    check hole from into container completely free

    make sure back of dryer is not in cold draught which may cause condensation in fan housing find more problems if dryer is used on delicate heat

    all i can think of
    hope it helps

    Dave

    #304295
    helo_75
    Participant

    spot on

    take the condenser out, put your arm in and feel for the hole, remove whatever is blocking it

Viewing 3 posts - 1 through 3 (of 3 total)
  • You must be logged in to reply to this topic.