    Hi Lads.

    I`ve got two of these with a similar fault.

    Every couple of months or so,the drier TOC trips and I have to go back and reset it.
    I`ve tested the drier operation and cannot find a fault.The fan runs fast enough,the water valve works and water enters correctly and the pump runs fine.
    The heater(it had gone o/c) and TOC has been changed on one and just the TOC on the other.
    On one of them there does`nt appear to be a cooling down period within the drier programme and it could be the same on the other which I`m going back to on Thursday.
    Both are not being used excessively or for heavy loads and are being allowed to finish the drying programme in full but still this intermittant tripping.

    Any suggestions?.

    Thanks.

    Chris.

    #304304
    superfix
    Participant

    Re: Siemens WPI1440 washer drier.

    Blocked condenser ?

    #304305
    Martin
    Participant

    Re: Siemens WPI1440 washer drier.

    Yep agreed…shoosh in the condenser ducting….common fault in washer dryers.

    #304306
    ChrisR
    Participant

    Re: Siemens WPI1440 washer drier.

    Thanks guys. 😀