resistance readings on windings

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries resistance readings on windings

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #50352
    bmrenr
    Participant

    Hi guys do you know what the minimum resistance readings should be on set of windings for a washing machine motor?

    Tom

    #304559
    Penguin45
    Participant

    Re: resistance readings on windings

    Brush motor? Surprisingly low – anywhere around 5 ohms through field and armature is typical – tacho circuit is usually rather higher.

    Penguin45.

    #304560
    bmrenr
    Participant

    Re: resistance readings on windings

    Cheers yes a brush motor im getting .8 of an ohm across one of the windings so I think new motor.

    Tom.

Viewing 3 posts - 1 through 3 (of 3 total)