resistance for NTC

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #50501
    wilf
    Participant

    anyone know the resistance reading for the wash NTC on an indesit WIDL102UK ? I’m getting 180k which I think seems a little high at room temp but it is a seperate NTC and in a metal tub. customer reporting a F1 fault (heater relay) but only on very hoy washes.

    wilf

    #305022
    Martin
    Participant

    Re: resistance for NTC

    I think the reading should be around about 20 to 25kΩ @ ambient temperature as a rule?

    #305023
    wilf
    Participant

    Re: resistance for NTC

    thats what I was thinking I’ll order one and see how it goes strange thing is I’ve never seen one go high resistance only O/C or S/C

    wilf

Viewing 3 posts - 1 through 3 (of 3 total)