zanusi

Viewing 6 posts - 1 through 6 (of 6 total)
  • Author
    Posts
  • #50589
    twinspark
    Participant

    hi ya what does e 20 mean
    parts relaced so far seized pump down to earth heater
    still will not pump or spin
    zwf 1230 w
    😆

    #305364
    A1engineer
    Participant

    Re: zanusi

    e20 is the customer viewed error code for no drain

    you need to access test program to find actuall error code eg e21,e22,e23,e24

    To enter diagnostics:

    1. Switch off the appliance.
    2. Press and hold down START/PAUSE and any one of the option buttons simultaneously.
    3. Holding down both buttons, switch the appliance on by turning the programme selector one position to
    the right (clockwise).
    4. Continue to hold down the START/PAUSE and option buttons until the LED begins to flash (at least 2
    seconds).

    In the first selector position, the operation of the buttons and the relative LEDs is checked; turning the
    selector knob clockwise activates the diagnostics cycle for the operation of the various components and
    displays any alarm conditions.

    #305365
    pup
    Participant

    Re: zanusi

    may be p.c.b gone?

    #305366
    wilf
    Participant

    Re: zanusi

    seized pump could take the board out make sure all new pumps have TOC fitted to protect the electronics

    wilf

    #305367
    Martin
    Participant

    Re: zanusi

    pup wrote:may be p.c.b gone?

    Indeed so and as you have changed both the pump (which would show an E20 error anyway) AND the heater then chances are the pump triac on the board has blown?

    Word of caution though first, before you just stick in a new PCB do take a close look at the surface components on the board to spot any signs of damage. I should hate you to go to the expense of fitting one and the same happens again. 😉

    #305368
    twinspark
    Participant

    Re: zanusi

    thanks every one 😮

Viewing 6 posts - 1 through 6 (of 6 total)
  • You must be logged in to reply to this topic.