Smart Drive GW501 error code 16

Home Forums Public Support Forums International Forums Australasian Appliance Forum Smart Drive GW501 error code 16

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #50756
    CheezeBeast
    Participant

    Howdy all,

    My machine has packed a sad and its displaying the error code 16 (00010000). Trouble is, my service manual skips over error code 16 so have no Idea what to do, does anyone know pretty please?

    …F&P Smartdrive GW501 (one of the first ones).

    #305856
    CheezeBeast
    Participant

    Re: Smart Drive GW501 error code 16

    17 – 20. (00010xxx) Phase 1 – Display / Motor Controller Out of Sequence
    22 – 23. (000101xx) Phase 1 – Display / Motor Controller Out of Sequence
    The Display Module and Motor Controller are running out of sequence.
    Primary Source
    Action
    Turn off Smartdrive at the wall and back on again after 5 seconds. Re-start.
    If fault persists disable auto restart feature and retest. A new fault code will appear. Carry out
    action of new fault details.

    I found this from the service manual, So how exactly do I disable the auto restart feature?

    #305857
    Penguin45
    Participant

    Re: Smart Drive GW501 error code 16

    Which way have you read the code? You should go right to left. 00001000 would be code 8, a recognised code for the display module failing.