Kupperbush W/D (zanussi) Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Kupperbush W/D (zanussi) This topic has 5 replies, 4 voices, and was last updated 16 years, 3 months ago by Steven. Viewing 6 posts - 1 through 6 (of 6 total) Author Posts December 15, 2009 at 2:52 pm #50972 StevenParticipant IWT1259.0W 914676003-00 Zanussi design has error code E00 on drying could not locate this code any ideas please ❓ Steven December 15, 2009 at 2:57 pm #306525 chris211Participant Re: Kupperbush W/D (zanussi) E00 on zanussi means no error code stored December 15, 2009 at 3:05 pm #306526 StevenParticipant Re: Kupperbush W/D (zanussi) Thanks for that Not been out yet! Ahh so does that mean there is a fault but just no error code related to this fault? Cheers will go and investigate. December 15, 2009 at 3:27 pm #306527 TheSpinDoctorParticipant Re: Kupperbush W/D (zanussi) Hi. E00 means that there are no faults that have been detected by the main electronic. What exactly are the reported symptoms? December 15, 2009 at 4:08 pm #306528 StevenParticipant Re: Kupperbush W/D (zanussi) You know customer explanations! Not working properly on drying :rolls: Runs for about 30 secs then slows down then starts up again 😕 Will be going out monday so will know more then. Thanks for your info. December 15, 2009 at 11:17 pm #306529 leavemetogetonwithitParticipant Re: Kupperbush W/D (zanussi) 💡 Maybe they’ve accidentally entered diagnostics/last fault detected mode. Mike. Author Posts Viewing 6 posts - 1 through 6 (of 6 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In