Home › Forums › Public Support Forums › Help And Support › Dishwasher Help Forum › John Lewis JLDWS1202 Not Heating
- This topic has 5 replies, 3 voices, and was last updated 16 years, 3 months ago by
bamforp.
-
AuthorPosts
-
December 22, 2009 at 8:40 pm #51143
bamforp
ParticipantMy John Lewis JLDWS1202 dishwasher no longer heats or drys the load during a cycle. There are no error codes and the cycle appears to run as normal apart from the lack of heat. I’ve checked the heater and it appears ok with a resistance of approx 25 ohm. Next thing to check I guess is the sensor but I’m not sure how to do this – any advice? It looks like it’s a multifunction device (I assume temperature and turbidity?) and has 4 wires connecting it to the wiring loom. Also if it is faulty any ideas where I can get a spare? I think the part code is DST1113160004
December 22, 2009 at 9:26 pm #307071Penguin45
ParticipantRe: John Lewis JLDWS1202 Not Heating
Burnt-out solder joint on the pcb is the most likely culprit.
Penguin45.
December 23, 2009 at 11:14 am #307072bamforp
ParticipantRe: John Lewis JLDWS1202 Not Heating
Thanks for the quick reply Penguin. There was indeed a bad joint under the relay which I have repaired. Unfortunately there is now a new error! After a couple of drain cycles it beeps twice repeatedly which according to the user guide is an outflow problem. I have tried putting some water in the sump and this is cleared easily so I don’t think it’s a blockage problem. I have also checked the pressure switch which appears clear so it brings me back to the sensor which I assume plays a part in sensing an empty sump. Is there any way to test the sensor or at least eliminate it as the source of the problem?
Thanks
December 23, 2009 at 7:23 pm #307073Penguin45
ParticipantRe: John Lewis JLDWS1202 Not Heating
If the water is pumping out but the machine thinks it’s still full (ie the pressure switch is holding in the full position), the fault may well be a blockage in the water matrix.
Penguin45.
December 24, 2009 at 1:52 pm #307074bamforp
ParticipantRe: John Lewis JLDWS1202 Not Heating
Matrix was full of crud so I removed it and gave it a good clean out. Still coming up with the same error. I read the post about perhaps needing a new matrix but the fact the drain fault only started after I ‘fixed’ the solder joint makes me wonder if the control board is faulty – perhaps I damaged it whilst repairing the relay joint? Time to call in a professional I think.
December 24, 2009 at 9:14 pm #307075TheSpinDoctor
ParticipantRe: John Lewis JLDWS1202 Not Heating
Hi.
It may be a fault with the pressure switch itself.
-
AuthorPosts
- You must be logged in to reply to this topic.