WFF1800gb/01 Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › WFF1800gb/01 This topic has 2 replies, 2 voices, and was last updated 16 years, 3 months ago by timdowning. Viewing 3 posts - 1 through 3 (of 3 total) Author Posts December 29, 2009 at 4:03 pm #51230 timdowningParticipant Never had this fault before; Whatever programme you select the timer just advances to the spin. It does the spin fine. Have tried resetting the programme, this machine has a selector and a timer. I have checked the obvious and all seems ok. I am assuming timer at fault. Any thoughts please. December 29, 2009 at 4:16 pm #307321 MartinParticipant Re: WFF1800gb/01 timdowning wrote:Any thoughts please. I’m thinking it could be that the air chamber is gunged up, that the heater may be o/c or duff inlet valve? Because usually with this model if there is a fault detected somewhere it just advances to spin anyway! HTH? December 29, 2009 at 4:36 pm #307322 timdowningParticipant Re: WFF1800gb/01 I thought the same. Valves, heater, pump all ok. I did wonder about the thermistor and pressure switch but didn’t venture that far. With the timer at £214 I didn’t want to write it off until I was sure. Thanks. Author Posts Viewing 3 posts - 1 through 3 (of 3 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In