HOTPOINT TDC30

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #5179
    PINKY
    Participant

    MORNING ALL.
    HAVE A PROBLEM ON HOTPOINT TDC30 CONDENSOR DRYER.AFTER A FEW MINUTES THE APPLIANCE GOES COMPLETLY DEAD.IF THE DOOR IS OPENED THE FILTER LIGHT COMES ON AS NORMAL.AFTER THE APPLIANCE HAS COOLED DOWN (APPROX 10 MINUTES)IT WILL RESTART AND RUN FOR A FEW MINUTES.HAVE CHECKED ALL THE OBVIOUS.CONNECTION BLOCKS,CUT OUT STATS ETC.,RELAY.LOOKING AT THE TIMER?YOUR IDEAS MUCH APPRECIATED! ❓

    #109381
    Albert
    Participant

    Re: HOTPOINT TDC30

    Hi Pinky,

    I had exactly the same fault on one of these driers a while ago, it was the relay that was causing it. Popped a new relay on and it’s been no trouble since.

    Regards
    Albert

    #109382
    technics1200
    Participant

    Re: HOTPOINT TDC30

    when i was at hotpoint we were told to change the start relays if this happens as the contacts are known to stick.

    #109383
    Penguin45
    Participant

    Hi Pinky,
    Take the serial number with you when you order – there are two relays (Well there would be, wouldn’dnt there – this “2nd time” Hotpoint after all).
    Regards,
    Penguin.

    #109384
    PINKY
    Participant

    Re: HOTPOINT TDC30

    😛 THANKS TO THOSE WHO REPLIED.TIMER SORTED THE PROBLEM.

Viewing 5 posts - 1 through 5 (of 5 total)
  • You must be logged in to reply to this topic.