February 7, 2010 at 1:47 pm #52301
robbra
ParticipantHi,
ongoing saga but started this one as it is the correct model.
Customer blew up the motor changing the brushes and now has replacement but….old motor has yellow socket with 2+4 connectors and his replacement has a white socket with 7 tags, one unused. Can it be modified to fit?
Thanks
RobFebruary 7, 2010 at 3:13 pm #311251iadom
ModeratorRe: Hotpoint WM52 motor exchange
Are both sockets flat, in line sockets, either 6 or seven connections as opposed to the much older double deck 3+3 motor plug.
It is possible to fit the six pin plug to the seven pin motor. you may have to snip off one or two of the lugs and turn the motor plug through 180°.
Identify which two connections on the new motor are from the tacho then make sure that the two wires that went to the tacho on the old motor line up with them, thats assuming you still have the old motor to check on.
New motor must not have a screw sticking out of the tacho end.
Jim.
February 7, 2010 at 4:12 pm #311252robbra
ParticipantRe: Hotpoint WM52 motor exchange
Thanks Jim,
They are both the old GEC type motors and the sockets are both in line flat and both in front of me now but not the machine. Will I still have to turn the connector though 180 or just rearrange the wires in the old connector block to line up with the tags in the new motor?
Thanks for the tech info too 🙂
RobFebruary 7, 2010 at 4:31 pm #311253aqualectric
ParticipantRe: Hotpoint WM52 motor exchange
WM52 should be using a Rast type motor plug: they have six or seven tags and the wires that come out the side of the plug. They have a Pin 1 indication marker above the position where the first wire goes in (right of the plug, IIRC). WM52 motors should be the 415 tacho type with the little metal ‘cross bar’ over the tacho coil. The wiring in the socket is (from the right to left):-
Far right tag – tacho
2nd – tacho
3rd – field
4th – field
5th – brush
6th – brush
7th – half winding for 1200 spin boost.If you’ve done an armature change and the motor still doesn’t work, check the wires from the motor socket to the brush terminal for continuity. If one lead is O/C, then the coil TOC has popped. (I think Qualtex still do replacements, or I’ve got some spare ones).
Hope that helps,
Steve.
February 7, 2010 at 6:54 pm #311254iadom
ModeratorRe: Hotpoint WM52 motor exchange
robbra wrote:Thanks Jim,
They are both the old GEC type motors and the sockets are both in line flat and both in front of me now but not the machine. Will I still have to turn the connector though 180 or just rearrange the wires in the old connector block to line up with the tags in the new motor?
Thanks for the tech info too 🙂
RobI thought you were still talking about an FHP motor replacement. 😳
No you don’t have to reverse the plug from one GDA motor to another, you can just plug it in as long as it is a digital motor. Two types of tacho/magnet used on the GDA/GEC digital motors the later one Steve mentions above with the tacho magnet screwed directly onto the motor shaft with no plastic washers on either side and the small bar over the tacho.
The other digital one has the old type larger tacho and a tacho magnet that has the plastic washers. The tacho magnet on this type of motor is much thicker than the one for the earlier, analogue controlled machines.
Jim.
February 7, 2010 at 7:11 pm #311255robbra
ParticipantRe: Hotpoint WM52 motor exchange
Both the old and replacement motors have the tacho with the bar, just different tag numbers and spacing in the socket so it should be plain sailing
February 7, 2010 at 7:23 pm #311256iadom
ModeratorRe: Hotpoint WM52 motor exchange
For future reference. 😉
The first one on the left is an analogue controlled motor tacho magnet.
Second one is an early digital type with the larger tacho coil and the last one is the later magnet which is the one you should have on both motors. The two types of digital motor are interchangable.

Jim.
February 9, 2010 at 7:25 pm #311257leavemetogetonwithit
ParticipantRe: Hotpoint WM52 motor exchange
Just come across this table on a retail spares site. Could be of use someday.
http://www.timms.biz/tech/gde-m-chart.php
Mike.February 9, 2010 at 8:06 pm #311258iadom
ModeratorRe: Hotpoint WM52 motor exchange
Link not working Mike 😥
February 9, 2010 at 8:07 pm #311259leavemetogetonwithit
ParticipantRe: Hotpoint WM52 motor exchange
Works OK from here. 😕
Mike.February 9, 2010 at 8:14 pm #311260iadom
ModeratorRe: Hotpoint WM52 motor exchange
Strange, I can get to this one. http://shop.timms.biz/
February 9, 2010 at 8:16 pm #311261BobHope
ParticipantRe: Hotpoint WM52 motor exchange
Works ok here too Mike.
Bob.
February 9, 2010 at 8:17 pm #311262iadom
ModeratorRe: Hotpoint WM52 motor exchange
Think it is a DNS problem, possibly not in the Ntl cache, will flush my DNS cache and try again.
EDIT. Working now. 😀
February 9, 2010 at 8:21 pm #311263goosegreen
ParticipantRe: Hotpoint WM52 motor exchange
Works for me Jim, Would have been handy in the past But not too many HP motor changes these days.
Goose
February 10, 2010 at 1:30 pm #311264leavemetogetonwithit
ParticipantRe: Hotpoint WM52 motor exchange
iadom wrote: a DNS problem, possibly not in the Ntl cache, will flush my DNS cache .
Not a clue what he’s talking about. 😆 These youngsters speak a different language. 😆
Mike. -