smeg DWi64 E3 Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › smeg DWi64 E3 This topic has 3 replies, 3 voices, and was last updated 16 years, 2 months ago by williamh. Viewing 4 posts - 1 through 4 (of 4 total) Author Posts February 9, 2010 at 9:35 am #52352 williamhParticipant just been to a smeg dwi64 and have got a E3 fault, checked heater element. anyone got any clues please. regards will. February 9, 2010 at 10:40 am #311446 Penguin45Participant Re: smeg DWi64 E3 From “Known Error Codes” thread: E3 – 1st, 2nd flashing, 5th lit – no heat in time allowed. Chris. February 9, 2010 at 11:38 am #311447 eastlmarkModerator Re: smeg DWi64 E3 williamh wrote:just been to a smeg dwi64 and have got a E3 fault, checked heater element. anyone got any clues please. regards will. is it heating? if not, some have a restable thermostat, or dry joint on heater relay on pcb or pcb itself if it only heats for a very short period. February 9, 2010 at 1:33 pm #311448 williamhParticipant Re: smeg DWi64 E3 thanks for that chaps i think it might be the pcb. i have checked the heater element and the thermostat so its pcb time. regards will. Author Posts Viewing 4 posts - 1 through 4 (of 4 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In