cda 447 d/w bottom spay arm no go Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › cda 447 d/w bottom spay arm no go This topic has 2 replies, 2 voices, and was last updated 16 years, 1 month ago by alro. Viewing 3 posts - 1 through 3 (of 3 total) Author Posts February 11, 2010 at 5:44 pm #52431 alroParticipant hi gents this cda447 no wash action on bottom spray arm top ok has a solniod vavle on cycle pump wot does this do if it divert the water to bottom arm as there is no 240v going to it form pcb any ideas no blckage in cycle pump cheers alro February 11, 2010 at 8:40 pm #311775 Penguin45Participant Re: cda 447 d/w bottom spay arm no go Alternator valve. Cheap fix is to remove plunger. Chris. February 11, 2010 at 10:59 pm #311776 alroParticipant Re: cda 447 d/w bottom spay arm no go thanks chris going back tomorrow cheers alan Author Posts Viewing 3 posts - 1 through 3 (of 3 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In