hotpoint wmd960puk f01……motor..?

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries hotpoint wmd960puk f01……motor..?

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #52469
    admin
    Keymaster

    HOTPOINT WMD960PUK
    hi, the machine is not that old…..but with indeshxt ,thats the way thay are!
    this one has come up with the f01. motor traic fault…ive Earth tested motor all ok .fitted new emw pcb , still no luck no motor action again.

    its got the induction motor in it (non carbon brush motor) i get readings from all the pins on the motor that its working ….but it…its a no goer. :rolls:

    before i fit a new motor ,are these motors playing up a lot like this ,
    and will a new motor snuff it again at such a young age,???? 😥

    manythanks

    canufixit

    #311910
    Phidom
    Participant

    Re: hotpoint wmd960puk f01……motor..?

    There is not a lot to go wrong on these motors. There are 2 thin wires from the tacho coil, the 3 stator wires for the 3 phases and 2 pale grey wires for the TOC. If these all give sensible meter readings it should work.

    #311911
    helo_75
    Participant

    ive had a lot of them where the wire breaks off in the motor plug

    rubbish, arent they

Viewing 3 posts - 1 through 3 (of 3 total)