  • #52846
    banditbarron
    Participant

    I have the above dryer and its not drying properly.

    The elements are heating up and have confirmed 230v to both also.

    The drum spins but clothes aren’t being dried.

    I thought maybe the fan part was faulty but it blows down the vent pipe so would presume its spinning?

    Any ideas before i order a new machine at £150?

    Thanks Dave

    #313356
    Penguin45
    Participant

    Re: White Knight 447WV

    Quite sure both elements are heating? Checking the supply only is firstly dangerous and secondly doesn’t tell you whether the relevant heater is actually working. Only a resistance test will tell you that.

    Penguin45.

    #313357
    banditbarron
    Participant

    Re: White Knight 447WV

    Hi penguine, both elements were warm when i first stripped it down but what ohms should i get through the loops?

    #313358
    Penguin45
    Participant

    Re: White Knight 447WV

    Approx 23 ohms per heater when split from the circuit – power off first.

    Penguin45.