Have had programer out no burt out relay have not looked at heater as it is a intergrated machine and sealed to flooring. Would the heater have to changed or just the plug in part. have not changed a heater what sort of job is it.
thanks Les
Hi
Went back to this machine today tested heater ok tested feed to heater ok tested machine on 3 programes all heating could this be the PCB relay and by moving the machine made it work ? HELLLLLP PLEASE
Les
The tubular heater should read approx 28 Ohms. I have had intermittent faults with the heater relays though but it’s always possible that you may have corrected a connection fault to the heater by unplugging & plugging it.
I would replace the board if this call comes back.