AEG W/D

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #53198
    robbo1973
    Participant

    914602122-01

    been here and fault code coming up is E72 which is fault in ntc on drying condensor,after looking on tds there is a sensor in the pipe at the bottom of the condensor and one in the dryer chamber i am thinking it must be the bottom one but can someone confirm this?

    cheers chris

    #314818
    chris211
    Participant

    Re: AEG W/D

    Yes you are thinking right it refers to the one on the condenser to tub hose, check the wires to the ntc they have a habbit of breaking older versions you can re-do the wires with tags but the later ones are idc type blocks.hope this helps

    #314819
    Tubs
    Participant

    Re: AEG W/D

    Agree with Chris

    NTC at the bottom, had this a while ago, loom etc ok. Turned out to be pcb

    Steve

    #314820
    TELL
    Participant

    Re: AEG W/D

    also make sure the condenser part is clear of fluff. gives the same fault.
    TELL.

    #314821
    Martin
    Participant

    Re: AEG W/D

    One more thought while you at it….take the NTC right out of that bottom hose and clean it. The sludge build-up in that bottom hose cakes the phial and leads to inaccurate readings. So while your cleaning the condenser ducting and checking the wires it’s best to kill 3 birds with one so to speak! 😉