Model : ZWD1471W
PNC : 904601126 00
Went out to this a few weeks back as it was erroring E10 on TD.
I took the back cabinet off and cleaned out the condensor however there was a bit of lint going up one side of it in a narrow tube part of the condensor that I couldnt shift but I improoved it by 99{e5d1b7155a01ef1f3b9c9968eaba33524ee81600d00d4be2b4d93ac2e58cec2d}.
Assumed job was done, charged customer. I then received a phone call saying that it did one load ok then on the seccond, stuff was coming out steamy after error code E10.
I checked the condensor solenoid which was ok. I then turned my attention to the drain pump and filter to make sure it was clear. I did find a piece of glass in the pump and customer informed me that he hadn’t heard the pump running at all on the TD cycle last time he used it.
Assumed that was it so left it with him.
Received another call saying its still the same, so I asked him to check the pump filter himself and he informed me it was totaly clear from glass and any debris.
I cant understand why this should be happening..
Any ideas please?
Thanks in advance.