    Hi

    I currently have error code 104 with the tub full and the pump making very quiet wirr wirr noises. I drained the tub and there appeared to be water dripping through the pump. Is there a secret to installing the pump so that there is a proper seal. I tested the pump and it showed 25 ohms. I had read it should be much higher. Is 25 ohms enough for the pump to work.


    Many thanks

    #317216
    Penguin45
    Participant

    Re: Fisher and Paykel GW709 Error Code 104 (01101000

    Pump should read c.33ohms. If water is running through the pump, the shaft seal is leaking and you need a replacement pump.

    104 is a comms error, so doesn’t collate with the machine not draining. Possible that a foreign object is lying above the pump inlet.