  • #54263
    scoobya1
    Participant

    have got a wd420 and a wml540, both fill and drain as soon as the programme starts and continue to do so. They are not syphoning. Any clues please

    #319013
    A1engineer
    Participant

    Re: hotpoint washers filling and draining as soon as prog st

    probably ntc fault, check wires at ntc if not needs a pcb

    #319014
    iadom
    Moderator

    Re: hotpoint washers filling and draining as soon as prog st

    If they start to fill on a spin programme then its 99{e5d1b7155a01ef1f3b9c9968eaba33524ee81600d00d4be2b4d93ac2e58cec2d} certain its the module.

    #319015
    garn
    Participant

    Re: hotpoint washers filling and draining as soon as prog st

    Just Left One Myself Continuous filling even In The 0 Position On The Selector Switch No Pump Or Motor Action 😥

    And The Stones Are Lose Looks Like Volcanic Dust All Over The Pcb 😮


    Garn

    #319016
    Allsorts
    Participant

    Re: hotpoint washers filling and draining as soon as prog st

    Check the two little blue NTC cables and the connectors on the module for bad connections

    George

    #319017
    scoobya1
    Participant

    Re: hotpoint washers filling and draining as soon as prog st

    was the ntc, lucky this time, thanks!