Diplomat APM8521 Washer

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #54366
    subs
    Participant

    This intergrated machine is struggling to rotate the drum. Without a load in it, if you put it on spin, when the drum starts to turn its very slow and laboured and then it finally gets going. The belt is not slipping. Is it a motor problem or could it be one or both of the capacitors i see it has? Are these motor start and run capacitors? One is uf22 the other uf16.

    Any Help Please

    Thanks

    Subs

    #319364
    aqualectric
    Participant

    Re: Diplomat APM8521 Washer

    Capacitors should be 20uF and 16uF…….. 😕

    Module is a DMPA type and is readily available from Tony at EMW.

    But before you order a replacement module, disconnect the heater first and try it on spin with a load in the drum. Earth leakage from the heater will cause no spin faults; so will a slack belt.

    Hope that helps,

    Steve.

    #319365

    Re: Diplomat APM8521 Washer

    Sounds like uf. The big 20’s go for fun.
    Mike.

Viewing 3 posts - 1 through 3 (of 3 total)