Tricity Bendix AW 1002 W keeps pumping.

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Tricity Bendix AW 1002 W keeps pumping.

Viewing 6 posts - 1 through 6 (of 6 total)
  • Author
    Posts
  • #54592
    DDDave
    Participant

    Hi Guys.
    The above machine keeps pumping. I changed the pressure switch but its still the same. Its not coming up with any fault code. Could it be anything other than the prog. module ??

    Thank you

    Dave

    #320247
    Seamy
    Participant

    Re: Tricity Bendix AW 1002 W keeps pumping.

    Go into diagnostics, step 2 should take in water, after filling empty out. switch on & off again. Sometimes that will reset it.

    #320248
    DDDave
    Participant

    Re: Tricity Bendix AW 1002 W keeps pumping.

    Seamy wrote:Go into diagnostics, step 2 should take in water, after filling empty out. switch on & off again. Sometimes that will reset it.

    Thanks Seamy, I will give it a go tomorrow.

    #320249
    MickGeorge
    Participant

    Re: Tricity Bendix AW 1002 W keeps pumping.

    Had a fault like this on a Tricity Bendix like this which after a lot of head scratching turned out to be a water valve shorting.

    If you inspect the valve you could see it had been overheating – never had one before or since but it is one of those jobs that stick in your memory because it was so unusual and wierd 🙂

    Worth a try before you order up a timer like i did!

    Mick

    #320250
    keithwilliams
    Participant

    Re: Tricity Bendix AW 1002 W keeps pumping.

    yes my first thoughts were water valve with very low coil resistance. only ever had it three times but as already said it sticks in the mind.

    #320251
    DDDave
    Participant

    Re: Tricity Bendix AW 1002 W keeps pumping.

    Going into diagnostics reset it. I have had another one do the same thing on Friday too !!
    Thanks for the help.