AEG ARCTIS 2792-4GA(928341004)

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries AEG ARCTIS 2792-4GA(928341004)

Viewing 7 posts - 1 through 7 (of 7 total)
  • Author
    Posts
  • #54650
    don1407
    Participant

    I have of these showing F8 evap frozen solid. Does anyone please have a list of fault codes or any info for this machine?

    Also machine has had pcb & sensors changed for F5 fault about a year ago.
    Going back when customer defrosted so any info would be helpful.

    Thanks in advance
    Ian

    #320445
    Penguin45
    Participant

    Re: AEG ARCTIS 2792-4GA(928341004)

    I can send you a general tech document in German, or a specific F8 document in Czech…..

    Chris.

    #320446
    don1407
    Participant

    Re: AEG ARCTIS 2792-4GA(928341004)

    Hi Chris

    That would be great the wife knows a bit of German & maybe can get enough info to point me in right direction, as for the czech one I will try & see if I can pick any info from it. Any info I can get would be helpful.

    Do you know if this was a none UK machine?


    Thanks again
    Ian

    #320447
    johnboy
    Participant

    Re: AEG ARCTIS 2792-4GA(928341004)

    Defrost heater open circuit

    #320448
    bigchrisoioi
    Participant

    Re: AEG ARCTIS 2792-4GA(928341004)

    its the ‘blanket’ heater o/c……its a stick on heater underneath the evaporator……..

    #320449
    don1407
    Participant

    Re: AEG ARCTIS 2792-4GA(928341004)

    Thanks for the reply
    But is it the defrost heater or the stick on drain heater, any clues? as I would like to be armed with a part for return visit & its a chargeable call so both are not an option.

    Thanks again

    Ian

    #320450
    bigchrisoioi
    Participant

    Re: AEG ARCTIS 2792-4GA(928341004)

    as i said above, stick on blanket heater will be the problem

Viewing 7 posts - 1 through 7 (of 7 total)