smegg dw dwf66ss

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #54819
    adv
    Participant

    cus sayin showing c8 fault any tips guys 😆

    #321075
    aqualectric
    Participant

    Re: smegg dw dwf66ss

    E8 is faulty water alternating valve. Usually leak slightly and stop: or the leak short circuits the switch on top. Slight water trace in the centre of the base tray is the giveaway……… 😉 Common problem.

    Hope that helps,

    Steve.

    #321076
    johnsdad
    Participant

    Re: smegg dw dwf66ss

    E8 is alternate valve fault

    #321077
    adv
    Participant

    Re: smegg dw dwf66ss

    thanks guys

Viewing 4 posts - 1 through 4 (of 4 total)
  • You must be logged in to reply to this topic.