  • #55389
    machineman
    Participant

    m/c floods. tested on rinse cycle
    does the first two rinses ok third rinse fills to low level fills again to normal level rinses for several mins then fill starts ,and does not stop
    is this the p switch?
    how do you check this type of pressure switch
    cheers Dave

    #323486
    Seamy
    Participant

    Re: zwf10070

    If its an analogic type device, it operates by generating a voltage of up to 5volts as the water level rises. PNC of machine would help as there are 5 versions of this model.

    #323487
    machineman
    Participant

    pin hole in pressure pipe. drove me up the wall
    thanks for the help
    Dave