  • #55579
    richardable
    Participant

    the main oven works fine.
    the grill oven is completely dead. have metered grill element and base
    element, both ok. metered the o/h stat ok, metered a stat on the central light fitting. no reading…should there be one?
    as soon as the grill oven is switched to any function the cooling fans run
    any other suggestions..?
    thanks
    richardable

    #324371
    peterjay
    Participant

    Re: NEFF D/O U1422NOGB/03 FD8601

    the stat on the light fitting is the overheat stat replace that

    #324372
    richardable
    Participant

    Re: NEFF D/O U1422NOGB/03 FD8601

    peter,
    thanks
    will post later
    richard

    #324373
    nomadPaul
    Participant

    I’d also give a visual check on the underneath of selector switch to have a look for any signs of burnt contacts .

    #324374
    richardable
    Participant

    Re: NEFF D/O U1422NOGB/03 FD8601

    sorry about late reply.. selector switch burnt.
    replaced…all now ok..
    thanks
    richard