    johnnyhoz
    Participant

    Hi all
    looking at the above tomorrow customer says it’s filling with the drain pump running at the same time and obviously never moves on

    any ideas please

    John

    #325683
    adv
    Participant

    Re: Servis M3005W filling / draining

    would say pcb 😆

    #325684
    robbra
    Participant

    Re: Servis M3005W filling / draining

    I agree,
    worth saving this one.
    Rob

    #325685
    superspin
    Participant

    Re: Servis M3005W filling / draining

    hi dont forget to check the waste hose isnt syphoning

    #325686

    Re: Servis M3005W filling / draining

    Some older Servis machines had water valve wired in series with pump so that if pump went o/c water valve would not turn on. This can create constant pump out when on rare occasions the water valve coil goes short circuit. If such has happened to cold valve but hot valve is still letting in water (or maybe vice versa) then you’d get fill + drain. (Probably.) OK it’s a long shot but worth bearing in mind. Can’t find much else to reply to today :lol:.