Ariston 1600wd F08 ?

Viewing 5 posts - 1 through 5 (of 5 total)
  • Author
    Posts
  • #56068
    allan73
    Participant

    Can somebody confirm light 1 (delay timer) is the dreaded f08 the same as on a hotpoint wf, before I order a board from EMW
    Thanks in advance Allan.

    #326141
    iadom
    Moderator

    Re: Ariston 1600wd F08 ?

    Comfirmation 😉

    #326142
    johnnyj
    Participant

    Re: Ariston 1600wd F08 ?

    Check the heater is not down to earth 1st, jj

    #326143
    allan73
    Participant

    Re: Ariston 1600wd F08 ?

    Will do johnny, have you had many heaters low on insulation throw up this code ?

    #326144
    johnnyj
    Participant

    Re: Ariston 1600wd F08 ?

    Yes had a few usualy caused by coins damaging it. JJ