Hotpoint WF220 Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Hotpoint WF220 This topic has 2 replies, 2 voices, and was last updated 15 years, 8 months ago by Mr66MARTIN. Viewing 3 posts - 1 through 3 (of 3 total) Author Posts August 5, 2010 at 8:44 am #56322 Mr66MARTINParticipant I have a problem with a hotpoint aqaurius WF220. when put on spin-It spins for say 5 seconds it does this 3 times then stops.both on/off & rinse hold flash together-it wont turn off.It has to be unplugged. Anyone help-Thanks August 5, 2010 at 9:47 am #326918 iadomModerator Re: Repair Moved you to correct forum. The ‘Known Error Codes’ thread at the top of this forum should be your first point of reference. 😉 Look HERE Fault is F02, motor jammed or tacho fault, I would be looking for broken wiring near the motor plug first. Welcome to the forums BTW. 8) Jim. August 26, 2010 at 10:47 am #326919 Mr66MARTINParticipant Re: Hotpoint WF220 Thanks for that. Turned out to be the PCB at faulty.Had it reconned.Works great now. Author Posts Viewing 3 posts - 1 through 3 (of 3 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In