Hi,
Struggling with this one.
Prod 911235209 pumps all the time. Base switch is fine as is pressure switch, so thought must be board so fitted new module. Same result. NTC reads about right resistance, no shorts in loom that I can see. Pump supply seems to be straight from board and thinking might be flood switch disconnected but that results in a warning tone so pretty certain not that!
Any ideas gratefully received.
Del.
Closest model no. I can find info for is F44080 via Connect mediator. Manuals seem to be slow downloading, lots of colour pics. There are two pressure switches apparently, including one described as an “anti-overflow”.
Can send basic manual if you give your e-mail address via PM. That’s private message not D.Cameron.
Mike.
Hi all,
Just thought I should post the answer to problem.
Heater was leaky, but not all the time, great. However new heater cured, but not until I had already bought and fitted new board.
delahart.