Fault 04 no heat. Tested dishwasher and …yup no heat!
Checked thermistor on front, stat, element and loom.All seem o.k.
I’m pretty sure its going to be the dreaded board, but is there any other known fault on these that causes no heat.???? 😕
Cheers
Tony C
Isn’t there a manual reset safety stat round the back of the sump moulding on these ones? If that’s tripped you’re more likely looking at a water level problem. Just an additional thought.
Iv’e not noticed one but it is something I was on the lookout for.
On the rear of the sump?I’ve had the panels off and nothings visible on this one.
Had that one a few times though usually the customer has”just tried a little washing up liquid in it cos we ran out of detergent” 🙄 . My how we laughed.
Then they got the bill 😈
Good and bad!
Fault correctly identified as heater circuit on board (thank you QER) 😀
Erm….Prat of an engineer 🙄 (me) made one of my connection marks on a component that was replaced . 😳
Anyone got a wiring diagram for one of these or know which way round the heater relay (white / brown) wires go.
😳
Tony C