    Had a look at one this morning, machine apprx 2 years old. Comes on ok, door locks but just sits there constantly with the drain pump running nothing else. Even the time display goes down as normal as if going through a wash. I let it go for 15 mins approx and no error code came up just keeps pumping. Anyone come across this , i presume board?

    #329722
    Martin
    Participant

    Re: Zanussi Jetsystem ZWF 14581 W

    Have you seen THIS THREAD?

    Email me with YOUR email address Micky and I’ll send you some stuff.:wink:

    #329723
    MickGeorge
    Participant

    Re: Zanussi Jetsystem ZWF 14581 W – continual pump out

    Must be in the air – been to an Electrolux EWN1478 with exactly same fault – didnt have any tech info 4 this as first one I have come across but found some on my Distriparts disc.

    No fault code coming up either altho I didnt have the info to put into diagnostic mode – but have now so looks like a return visit.

    I didnt see any other board other than the main pcb so doubt whether this is the inverter board.

    Funny enough just been reading this thread before I went altho cust didnt say about pumping out all time just that it wouldnt start program.

    Mick

    #329724
    bigchrisoioi
    Participant

    Re: Zanussi Jetsystem ZWF 14581 W

    anti flood in base????…….’efo’ fault code in diagnostics?

    #329725
    MickGeorge
    Participant

    Re: Zanussi Jetsystem ZWF 14581 W

    Hi Folks

    Been back to this today – put into diagnostic mode check/reset and m/c now working ok :rolls:

    They tell me they have young child who is constantly messing with controls when m/c on – suspect he may have caused computer to freeze some how and entering diag. mode has reset it – unfortunatly had left tap switched off from last visit and not realized so produced a no fill fault when doing a componant test which over road any previous fault code 😳 so no clue what that might have been.

    Showed them how to use the child lock facility and ring again if produces the same fault.

    Not sure if this helps Micky?