Bosch WTE84102GB/03 Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › Bosch WTE84102GB/03 This topic has 5 replies, 3 voices, and was last updated 15 years, 7 months ago by nigegt. Viewing 6 posts - 1 through 6 (of 6 total) Author Posts September 8, 2010 at 12:17 pm #57102 nigegtParticipant Customer presses start button, it beeps and the first, second and fourth light down the front flash. Any ideas what this code means? Thanks Nige September 8, 2010 at 1:16 pm #329809 MartinParticipant Re: Bosch WTE84102GB/03 I don’t know but I wouldn’t mind betting it’s to do with turning it off before cool-down and the TOC on the heater has tripped? 💡 September 8, 2010 at 4:24 pm #329810 nigegtParticipant Re: Bosch WTE84102GB/03 Thats what i hoped for but went earlier and all seems well but couldn’t get it to fire up 😕 Nige September 8, 2010 at 5:12 pm #329811 nomadPaulParticipant do 1st , 2nd and 4th led’s equate to drying , iron dry and end ? If so , the thats F:11 which is a control fault detected which normally means a new control module i think !! September 9, 2010 at 8:05 am #329812 nigegtParticipant Re: Bosch WTE84102GB/03 Hi Yes they do, I’ll get one priced up and let ’em know Cheers September 13, 2010 at 10:12 am #329813 nigegtParticipant Re: Bosch WTE84102GB/03 Control mod fitted, sorted problem thanks Nige Author Posts Viewing 6 posts - 1 through 6 (of 6 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In