Zan ZWF12070W1 Auto Overheating?

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Zan ZWF12070W1 Auto Overheating?

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #57213
    laurenceuk
    Participant

    Hi,

    914521912(00)

    Customer complains that machine has overheated on three different low
    temp (40C) washes to the extent that the glass door is too hot to touch and
    the utility room is abnormally hot when entered.

    Machine will finish program.

    Is there a known problem with these or am I to first try an NTC replacement
    in the heater or suspect the board?

    Can the heater mounted stat be purchased separately?

    Thanks

    Laurence

    #330259
    Seamy
    Participant

    Re: Zan ZWF12070W1 Auto Overheating?

    Would be trying a new NTC first. Theres a heater in it with fuses in line so you must replace with same, check part num’ on flange of old heater to be sure. NTC not listed as spare on its own but comes in new heater. Board could also be at fault though.

    #330260
    laurenceuk
    Participant

    Re: Zan ZWF12070W1 Auto Overheating?

    That’s great Seamy.

    Thanks for your response.

    Laurence

Viewing 3 posts - 1 through 3 (of 3 total)