Hotpoint Dryer Mod TCD970P

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #57363
    smeghead
    Participant

    After 10 mins , Error F07, All option lights flash, but machine continues to run.
    Done all usual checks, gunge in pumping tank base, cleaned out but error still occurs.
    Any Help appreciated. Clive.

    #330943
    BobHope
    Participant

    Re: Hotpoint Dryer Mod TCD970P

    F07 Lower element failure • Check security of module connector J4;
    • Test between pins 4 and 3 on J4 (approximately 48 Ohms);
    • If open circuit, test lower element and wiring between J4
    and the heater.

    Bob.

    #330944
    smeghead
    Participant

    Re: Hotpoint Dryer Mod TCD970P

    Thanks for that Bob, seems to heat OK but will check connections on module & recheck heater resistance.
    Clive.