Belling XOU90G Gas Cooker

Viewing 3 posts - 1 through 3 (of 3 total)
  • Author
    Posts
  • #57519
    sunrunner
    Participant

    Has anyone come across this problem before? It’s regarding the grill burner with floppy flames licking out of the cavity. Grill burner and top oven thermostat have been replaced but have made no difference. Our engineer believes there is a cooling fan. Should this run all the time and does it affect the burner flame? The correct injector is installed. This is a fault which developed between uses. Any suggestions would be appreciated.

    #331393
    barneyb
    Participant

    Re: Belling XOU90G Gas Cooker

    Your Engineers is right there should be a fan at the rear of the oven which is controled by a PCB it cuts in after a short time then can run on after the oven is switched off
    The flames are being starved of air Check out the fan by using a direct Feed.. If not its the PCB

    #331394
    sunrunner
    Participant

    Thanks barneyb. I’ll send him with a cooling fan and PCB and hopefully we’ll knock this one on the head. I appreciate your help. Cheers.