Hoover HNC382T-80 condenser dryer, stopping after a while.

Home Forums Trade Technical & Spare Parts Forums Trade Technical Enquiries Hoover HNC382T-80 condenser dryer, stopping after a while.

Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #57753
    Rograbbit
    Participant

    Hi folks. Been out to this one. Machine starts then after a short while stops. Quite often reaches reversing section before cutting out. It is then difficult to get it to start again, almost like start relay not staying in. This is a pcb controlled machine. Pressure switch on this one was also holding pressure, customer runs it into a stand pipe instead of the tank, blockage maybe? Any technical info would be appreciated. Thank you. 🙂

    #332161
    Martin
    Participant

    Re: Hoover HNC382T-80 condenser dryer, stopping after a whil

    I’ve sent you something to your email address listed on your web site. 😀

    #332162
    keithwilliams
    Participant

    Re: Hoover HNC382T-80 condenser dryer, stopping after a whil

    front exhaust stat at filter housing. nc85 degrees. that sorted one for me last thursday.
    keith

    #332163
    Rograbbit
    Participant

    Re: Hoover HNC382T-80 condenser dryer, stopping after a whil

    Thank you for your information gents. Will go back armed 😀