Viewing 4 posts - 1 through 4 (of 4 total)
  • Author
    Posts
  • #57845
    oscar123
    Participant

    This m/c will not heat on dryer.. runs for whatever time is set blowing cold air, no error code in shown. Elements, bi metal stats OK, I have tried a new NTC. 240v to elements but no neutral path. Can anbody suggest another possible cause before I quote for a new module?
    Oscar

    #332476
    Bernie
    Participant

    Re: Zanussi ZWD1682W

    If you would like the wiring diagram for this machine let me have your email address

    Bernie

    #332477
    Grendal
    Participant

    Re: Zanussi ZWD1682W

    Have you checked the lower ntc on the condenser,usually a broken wire

    #332478
    oscar123
    Participant

    Re: Zanussi ZWD1682W

    Sorry for late reply been on holiday 🙂 thanks for your help! broken wire to lower ntc. Never thought of looking there. Thanks again.
    Oscar.