October 12, 2010 at 4:48 pm #57926
Alanj
ParticipantHi Guys, went to fit replacement stat for this fridge today only to find appliance has original 2 terminal stat fitted and the replacement has 3 terminals. Any Hotpoint/Indesit engineers got any details of new wiring/technical bulletin?
Alan
October 12, 2010 at 5:34 pm #332695iadom
ModeratorRe: Indesit SAN300UK (34532)
You have the wrong stat. Model is a SAN300UKZ
Two different stats used, two tag one is a 2604182.
Jim.
October 12, 2010 at 5:44 pm #332696Alanj
ParticipantRe: Indesit SAN300UK (34532)
Hi Jim, I have tried inputting that number into Connections but it still comes up with three term stat. Masterpart comes up with part number
C00141230 but no picture and if you input this number to Connect it comes up with 3 term stat.Alan
October 12, 2010 at 5:46 pm #332697Alanj
ParticipantRe: Indesit SAN300UK (34532)
also there is no Z listed on the appliance but the 34532 is quoted on connect when looking up indesit appliances.
Alan
October 12, 2010 at 5:47 pm #332698iadom
ModeratorRe: Indesit SAN300UK (34532)
The info I have given is from the latest edition of Partfinder.
The three tag one is to switch the inner light off when the stat is in the OFF position.
There are many different models of the SAN300.
The SAN300UK is a Hotpoint badged machine, commercial code 61742.
The SAN300UKZ is badged as Indesit, commercial code 34532 which has two different stats.
October 12, 2010 at 5:59 pm #332699Alanj
ParticipantRe: Indesit SAN300UK (34532)
Jim here is all numbers off inside of machine at back of salad bin.
IND 76 34532 7600
S/N608300029
SAN300UKAlan
October 12, 2010 at 6:04 pm #332700iadom
ModeratorRe: Indesit SAN300UK (34532)
Yep, that commercial code, 34532 brings up a SAN300UKZ on Partfinder (and elsewhere)
Two tag stat fitted before serial number 80531.9999.
I would have thought that it would be possible to fit the stat you have in place of a two tag one but not vice versa.
No obvious tech info on it though.
October 12, 2010 at 6:09 pm #332701Alanj
ParticipantRe: Indesit SAN300UK (34532)
SAN300UKZ not listed on Connect or Masterpart?
Alan
October 12, 2010 at 6:25 pm #332702Alanj
ParticipantRe: Indesit SAN300UK (34532)
Can any one help with this problem?
Alan
October 12, 2010 at 6:27 pm #332703iadom
ModeratorRe: Indesit SAN300UK (34532)
Doesn’t mean to say that a SAN300UKZ does not exist. 😉
Can you not work out which two terminals control the compressor on the new stat, the three terminal one is only to allow the interior light to be switched off via the stat.
October 12, 2010 at 6:44 pm #332704Alanj
ParticipantRe: Indesit SAN300UK (34532)
I would assume that if terminal 3 is for switching the light off then 1 and 2 would be the connections? 😕
Alan
October 12, 2010 at 6:47 pm #332705Simon46
ParticipantRe: Indesit SAN300UK (34532)
not 6 live in and 4 out to compressor? light to be connected on 6 side.
S.
October 12, 2010 at 6:59 pm #332706Alanj
ParticipantRe: Indesit SAN300UK (34532)
Hi Simon,
what are the connections for compressor using only 2 of the three terminals 6 and 4? Terminal 3 not required?Alan
October 12, 2010 at 7:11 pm #332707Alanj
ParticipantRe: Indesit SAN300UK (34532)
Problem solved Live to 6 and compressor to 4 (2). Stuck phial in freezer and tested operation. 😀
Alan
October 13, 2010 at 12:35 am #332708gandh1
ParticipantRe: Indesit SAN300UK (34532)
from our experience tho its a bit unlikely to be a stat tho, h/p indesit have seen 3 of our san300s getting overy warm already this year under warranty, and we have had to replace all of them now. and thats 2 too many for our boss to continue to stock them… and all had the stats replaced as an initial fix by hp about 4 weeks after tehy went wrong…
-