Re: SCHRIBER APM 6855 F/F
Yes a Common Problem
If the evap is full of Hoar Frost:
Disconnect the Power from Mains
Re-connect the Power
If the heater fails to heat up or the compressor kicks in
You can be 99{e5d1b7155a01ef1f3b9c9968eaba33524ee81600d00d4be2b4d93ac2e58cec2d} sure it is the Evap Sensor – Oddly Named “radiator probe” by Connect
By the way, I think the:
Samsung Sensor DA32-00006W is the same resistance/voltage
You can splice a new Sensor into place. Make sure you solder/heat shrink or both.
TM