this w/d seems to release its interlock at random in the wash cycle,any one seen this b4.suspect board but thought i would just ask first,thanks richard. 😕
dryer heaters are known to cause all sorts of errors, check its not reading down to earth, disconnect all cables to dryer heater & see if problem is resolved
Strange fault that. Have you seen it for yourself? I’ve had one where the machine would fill, start washing, or rinsing, then go straight to drain and once drained open the door (clunk clack). That one was a burnt out recirculation pump which had also taken out a small ac switch on the board. So I would suggest look see if recirculation pump is either dead or intermittent.
Also see this.
Mike.
mike the description from them is vague as usual,i have not been yet but i think you are spot on the same thing here.circulating pump eh,its given me a start point many thanks richard, 🙂