smeg wdi 12c Home › Forums › Trade Technical & Spare Parts Forums › Trade Technical Enquiries › smeg wdi 12c This topic has 3 replies, 3 voices, and was last updated 15 years, 5 months ago by funkyboogy. Viewing 4 posts - 1 through 4 (of 4 total) Author Posts October 19, 2010 at 6:57 am #58100 funkyboogyParticipant not been yet customer reporting e4 and e6 ..oh joy any ideas where to start cheers ally October 19, 2010 at 6:28 pm #333384 LawrenceParticipant Re: smeg wdi 12c look for a broken thermistor wire bottom of tub approx 5 oclock as you look at the back October 19, 2010 at 10:38 pm #333385 eastlmarkModerator Re: smeg wdi 12c and E6 is a slow drain fault, 5p in the pump outlet or a blocked air bell. November 2, 2010 at 8:08 am #333386 funkyboogyParticipant Re: smeg wdi 12c hello troops , e6 was 5p in drain still have e4 … thermister wires looked ok …. this is a insu job would it be best to quote for pcb and thermister … cheers ally Author Posts Viewing 4 posts - 1 through 4 (of 4 total) You must be logged in to reply to this topic. Log In Username: Password: Keep me signed in Log In