July 12, 2004 at 8:41 am #5817
BobHope
ParticipantHelp requires on this one lads,
Customer error code E20, Service error code E22,
No faults on wash cycle, drain circuit checked, blower motor ok, condenser valve ok, dryer heater ok, in its test sequence the fault shows up after 30 secs of running,
must be a silly oh i have reconfigerd the pcb still the sameCheers Bob.
July 12, 2004 at 9:37 am #113927Dave_Conway
ParticipantRe: Zanuusi WJS1265W Washer Dryer
Bob, as described by the technical info I have:
E22:
Problems with water drain during drying or
drying condenser blocked
(anti-boiling pressure switch closed
on “full”)
E20:
Heating phase
skipped
Drain hose obstructed; filter blocked; drying
condenser blocked; drain pump; pressure
switches; wiring; main PCBDave.
July 12, 2004 at 10:18 am #113928BobHope
ParticipantRe: Zanuusi WJS1265W Washer Dryer
tried them all Dave,
they all seem ok,
strange one this time.July 12, 2004 at 10:24 am #113929Dave_Conway
ParticipantRe: Zanuusi WJS1265W Washer Dryer
It can only be the main PCB then, or have you replaced that as well ?
Dave.
July 12, 2004 at 11:34 am #113930BobHope
ParticipantRe: Zanuusi WJS1265W Washer Dryer
not changed the pcb Dave but i have reset the option bytes.
January 11, 2009 at 8:11 pm #113931keithwilliams
ParticipantRe: Zanuusi WJS1265W Washer Dryer
did you ever get to the bottom of this one?
my nieces machine is doing exactly the same. machine is only two years old. have checked pressure switches drain out etc.
any advice would be great
thanks
keithJanuary 12, 2009 at 1:27 am #113932aqualectric
ParticipantRe: Zanuusi WJS1265W Washer Dryer
I’ve had this problem before – the condenser was badly blocked. The machine would drain out fully, then fault E20. Pump and filter (usual culprits for an E20 fault code) were both clear and working. Pressure chamber was clear as well.
It seemed that enough water was being retained behind the blockage to stop the analogic pressure switch from sensing an empty machine (therefore slowly emptying and refilling the sump causing a time out on drain) thus preventing a spin. Cleaned the condenser and hey presto!! All OK. The analogic pressure switch must be very sensitive……….:?Strange fault….. 😉
Steve.
March 22, 2012 at 9:49 am #113933iadom
ModeratorRe: Zanuusi WJS1265W Washer Dryer
Dragging one up from the distant past. 🙂
I have an AEG L16830 throwing up E22. Pnc: 194602122-01
I went a couple of days ago, it was showing error code for a flooded base, sure enough the small grey plastic drain hose from the pump to the filter flap had come adrift.
Refitted, tested all functions OK.
Now its showing E22.
Pump, filter, outlet hose all perfect. Dryer heater insulation fine. Condensor completely clear ( I fitted a new fan motor 6 months ago to cure a screaming motor noise )
I did notice that when set on a drying programme it drains for a couple of seconds and then sounds to be trickling water through the dryer valve and the drum is turning, it does take about 35 to 45 seconds or more before the fan and heater kick in though, is this normal?
Jim.
March 22, 2012 at 10:31 am #113934Martin
ParticipantRe: Zanuusi WJS1265W Washer Dryer
iadom wrote:Now its showing E22.
Does the error throw up on a wash or a dry cycle Jim?
(Fan and element kicking in after 30 odd seconds is normal)
March 22, 2012 at 10:56 am #113935iadom
ModeratorRe: Zanuusi WJS1265W Washer Dryer
Only on the drying cycle Martin, I did run it for about 20 minutes without any problems yesterday. I also swapped the aquastop type hose for a normal one to eliminate poor fill as a possibility.
No call back yet but it was only yesterday afternoon so will have to see how it goes.
Jim.
March 22, 2012 at 12:32 pm #113936Martin
ParticipantRe: Zanuusi WJS1265W Washer Dryer
iadom wrote:No call back yet but it was only yesterday afternoon so will have to see how it goes.
Well if you do get a recall I can only suggest you take a closer look at the condenser, especially the bottom hose and the attached NTC. 😉
March 22, 2012 at 2:14 pm #113937iadom
ModeratorRe: Zanuusi WJS1265W Washer Dryer
Unless she is washing woollen blankets for the street I don’t think it is blocked.
I did have to strip the condensor down about 12 months ago to hose it out and as mentioned had the back off to change the fan motor quite recently so checked on the condensor at the time.
Still “stranger things” and all that. 😀
Jim.
-