  • #58283
    spimps
    Participant

    Had the F-03 fault so replaced ntc and element,fault cleared fault started programme started to heat OK,then cancelled and set to drain,no pump,sometimes no pump sometimes 45 seconds run and then neutral return from pump shows 240v at the board so pump stops.
    Checked all connections,squeezing up and lifting the tags slightly,ran pump independantly for several minutes.
    PCB ! ?
    Any info on this ie diagram please.
    Brian

    #333985
    iadom
    Moderator

    Re: WF360

    You got mail. 😉

    #333986
    spimps
    Participant

    Re: WF360

    Thanks Jim,
    Have thought about adding a nuetral link direct to the pump.
    Worth a try perhaps.