ISE 10 1606W no drum action ‘F1’ fault.

Home Forums Manufacturer/WP/Insurer Specific Forums ISE Trade Support Forum ISE 10 1606W no drum action ‘F1’ fault.

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #58382
    boselecta
    Participant

    Had a call last week with ‘F1’ fault, found no drum action with appliance. Replaced inverter module at base, machine spins all functions working ok.

    Customer has just called me to say it worked a few times now no drum action and ‘F1’ in display!.

    Definatley no blockages in pump or pressure system bloackage.

    any ideas guys?

    #334383
    aqualectric
    Participant

    Re: ISE 10 1606W no drum action ‘F1’ fault.

    F1 with just the first red segment around the start/door open switch indicates a door not closed problem.
    F1 with all the segments light up means an overfill problem.

    don’t forget to reset the program (holding start button down for 5 secs, switching off/unplugging will not re set it) before testing as it will still flag up the error code even if the fault has been repaired. (info:- courtesy of eastlmark)

    Hope that helps,

    Steve.

Viewing 2 posts - 1 through 2 (of 2 total)
  • You must be logged in to reply to this topic.