SMEG DW 1612C

Viewing 2 posts - 1 through 2 (of 2 total)
  • Author
    Posts
  • #58418
    M1
    Participant

    This DW on all programs just washes for hours the heater is ok but never seems to get 240V to it. The live comes from the presure switch (is this working Ok ?) The neutral is switched through the power relay on the PCB.
    Can’t find a thermister for the heater just a thermal cut out in the door.
    No broken wires, pre wash works fine because the heater function is not used.

    No fault LEDs on just 2 beeps every couple of minutes.

    Any ideas or am I totally barking up the wrong tree.

    Thanks

    #334500
    eastlmark
    Moderator

    Re: SMEG DW 1612C

    would go for the pcb as you have checked everything else it could be. Pressure switch is easy enough to test and a rare faulure.

Viewing 2 posts - 1 through 2 (of 2 total)